c020: 10 Gb/s 10Km(SMF) Bi-Di SFP+ Optical Transceiver
Æ®·£½Ã¹ö 1 : T1270nm/R1330nm

Æ®·£½Ã¹ö 2 : T1330nm/R1270nm

.
Product Features
- Single LC Connector
- Support hot-pluggable
- Metal with lower EMI
- Excellent ESD protection
- Distance up to 10Km on 9/125um SMF
- Single 3.3V power supply and Low power dissipation <1.2 W
- GR-253-CORE compliant
- Compliant with IEEE 802.3ae
- RoHS Compliant and Lead-Free
- Compliant with SFP+ MSA: SFF-8431 Rev4.1
- Compliant with SFF-8472 Rev11.0
Applications
- 10GBASE-LR/LW
- 10G Fibre Channel
- Other optical link
Product Selection
Part Number |
Wavelength |
DDMI |
c021-1 |
Tx-1270 / Rx-1330 |
Yes |
c021-2 |
Tx-1330 / Rx-1270 |
Yes |
Pin Descriptions
Pin |
Symbol |
Name/Description |
Ref. |
1 |
VeeT |
Transmitter Ground (Common with Receiver Ground) |
1 |
2 |
TX Fault |
Transmitter Fault. LVTTL-O |
2 |
3 |
TX Disable |
Transmitter Disable. Laser output disabled on high or open. LVTTL-I |
3 |
4 |
SDA |
2-Wire Serial Interface Data Line(Same as MOD-DEF2 in INF-8074i). LVTTL-I/O |
|
5 |
SCL |
2-Wire Serial Interface Data Line(Same as MOD-DEF2 in INF-8074i). LVTTL-I |
|
6 |
Mod_ABS |
Module Absent, Connect to VeeT or VeeR in Module. |
4 |
7 |
RS0 |
Rate Select 0, optionally controls SFP+ module receiver LVTTL-I |
5 |
8 |
LOS |
Loss of Signal indication. Logic 0 indicates normal operation. LVTTL-O |
2 |
9 |
RS1 |
Rate Select 1, optionally controls SFP+ module transmitter. LVTTL-I |
5 |
10 |
VeeR |
Receiver Ground (Common with Transmitter Ground) |
1 |
11 |
VeeR |
Receiver Ground (Common with Transmitter Ground) |
1 |
12 |
RD- |
Receiver Inverted DATA out. AC Coupled. CML-O |
|
13 |
RD+ |
Receiver Non-inverted DATA out. AC Coupled. CML-O |
|
14 |
VeeR |
Receiver Ground (Common with Transmitter Ground) |
1 |
15 |
VccR |
Receiver Power Supply |
|
16 |
VccT |
Transmitter Power Supply |
|
17 |
VeeT |
Transmitter Ground (Common with Receiver Ground) |
1 |
18 |
TD+ |
Transmitter Non-Inverted DATA in. AC Coupled. CML- I |
|
19 |
TD- |
Transmitter Inverted DATA in. AC Coupled. CML- I |
|
20 |
VeeT |
Transmitter Ground (Common with Receiver Ground) |
1 |
Notes:
1. The module signal ground contacts, VeeR and VeeT, should be isolated from the module case.
2. This contact is an open collector/drain output and should be pulled up to the Vcc_Host with resistor in the range 4.7K¥Ø to 10K¥Ø. Pull ups can be connected to one or several power supplies, however the host board design shall ensure that no module contact has voltage exceeding module VccT/R +0.5V.
3. Tx_Disable is an input contact with a 4.7K¥Ø to 10K¥Ø pull-up resistor to VccT inside module.
4. Mod_ABS is connected to VeeT or VeeR in the SFP+ module. The host may pull the contact up to Vcc_Host with a resistor in the range from 4.7K¥Ø to 10K¥Ø. Mod_ABS is asserted ¡°High¡± when the SFP+ module is physically absent from a host slot.
5. RS0 and RS1 are module inputs and are pulled low to VeeT with > 30 k¥Ø resistors in the module. RS0 optionally selects the optical receive signaling rate coverage. RS1 optionally selects the optical transmit signaling rate coverage.
Pin-out of Connector Block on Host Board

Recommend Circuit Schematic




Notes:
1. BER ¡Â10-12 @PRBS231-1 at 10.3125Gb/s.
2. The Wavelength for p103
3. The Wavelength for p104